Refractory Materials

Refractory Castables

Model / part reference: GYM-1 / GYM-2 / GYM-3

GYM-1, GYM-2 and GYM-3 castables for furnace and boiler lining requirements.

Refractory castables for shaped-in-place lining work. The reference table distinguishes composition and strength after the stated drying or heating conditions. Specify installation method, lining thickness, operating temperature and exposure. Mixing, curing and dry-out procedures must be agreed for the selected material.

Typical Application

Boiler and furnace lining sections, including arches, roofs and rear walls. Confirm the exact lining position and service conditions.

Customization & Replacement

Send the equipment and lining or casting position, drawing or dimensions, operating temperature, steel or process grade, existing material specification and required quantity. Test methods, installation requirements and supply scope are confirmed before quotation.

Send drawings, part numbers or photos and your required quantity. Supply scope and technical requirements are reviewed before quotation.

GYM-series reference properties

GYM-series reference properties
Property / conditionUnitGYM-1GYM-2GYM-3
Al2O3%≥70≥75≥85
SiO2%≤25≤20≤10
Bulk densityg/cm³≥2.7≥2.8≥2.95
Modulus of rupture at room temperature, after 110°C × 24 hMPa≥10≥11≥12
Modulus of rupture at room temperature, after 1500°C × 3 hMPa≥12≥14≥15
Cold crushing strength, after 110°C × 24 hMPa≥80≥90≥100
Cold crushing strength, after 1500°C × 3 hMPa≥100≥110≥120
Permanent linear change, after 1500°C × 3 h%±0.3±0.3±0.3
Thermal shock resistance, 1100°C water coolingcycles≥25≥25≥15
Abrasion loss at room temperaturecm³≤8≤7≤6
Maximum service temperature (reference)°C1550ConfirmConfirm

Reference grade data; test methods and acceptance requirements must be agreed. The temperature value is listed for GYM-1 only; confirm the service-temperature limit for GYM-2 and GYM-3 and for the actual duty.

Related Products